Specifications
Technical specification
| Model: BP-FD-ACP300-1L | ||
| Power Supply | ||
| Mains supply | 230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A | |
| Mains fuse | T3.15AL250V | |
| Operating voltage | 18.5 ~ 30VDC | |
| Recommended mains cable | Screened or standard/black mains cable, cable size 0.75mm2 | |
| Power rating | Imax.a=1.2A; Imax.b=2.6A; Imin=0.65A | |
| Max. charging current | 1.2A | |
| Max. battery supply current | 4A (when the Mains is disconnected) | |
| Battery capacity, type and
recommended model |
Max. capacity 2×12V/17Ah; Min. capacity 2×12V/12Ah
VRLA. PS-12170 for 17Ah (Power-sonic), PS12120 for 12Ah (Power-sonic) |
|
| Max. internal resistance of battery | 1.5Ω | |
| Battery fuse | F8AL250V | |
| Recommended battery cable | 14AWG | |
| Quiescent current (full loaded) | < 0.4A | |
| Outputs | ||
| S.C. Out (+, -) | Output voltage | 18.5 ~ 30VDC |
| Max. output current | 0.5A | |
| Fuse rating | F1AL250V | |
| End of line resistor | 4K7 | |
| Recommended type of cable | Plain unscreened cable, 1.5mm2 | |
| Cable diameter | 1mm2 ~ 2mm2 | |
| Transmission distance | ≤1500m | |
| Max. number of sounders @50mA | 20 | |
| F.P.E. Out (+, -)
F.A. Out (+, -) |
Output voltage | 18.5 ~ 30VDC |
| Max. output current | 0.5A | |
| Fuse rating | F1AL250V | |
| End of line resistor | 4K7 | |
| Recommended type of cable | Plain unscreened cable, 1.5mm2 | |
| Cable diameter | 1mm2 ~ 2mm2 | |
| Transmission distance | ≤1500m | |
| Fault Out
(NC, COM, NO) |
Contact capacity | 30VDC@2A, 125VAC@0.5A |
| Recommended type of cable | Plain unscreened cable, 1.5mm2 | |
| Cable diameter | 1mm2 ~ 2mm2 | |
| 24VK (+, -) | Output voltage | 18.5 ~ 30VDC |
| Max. output current | 0.6A | |
| Fuse rating | F1AL250V | |
| Recommended type of cable | Plain unscreened cable, 1.5mm2 | |
| Cable diameter | 1mm2 ~ 2mm2 | |
| Input | ||
| Class change (+, -) | Input mode | Passive |
| Cable resistance | ≤500Ω | |
| Recommended type of cable | Plain unscreened cable, 1.5mm2 | |
| Cable diameter | 1mm2 ~ 2mm2 | |
| Loop | ||
| Loop Out (+, -)
Loop In (+, -) |
Output voltage | 16.5 ~ 30VDC, pulse |
| Output current | 0 ~ 0.3A | |
| Loop type | Class A | |
| Recommended type of cable | Screened or unscreened twisted-pair, 1.5mm2 | |
| Transmission distance | ≤1000m | |
| Cable diameter | 1mm2 ~ 2mm2 | |
| Network communication | ||
| RS-485 | Max. number of FIPs | 30 |
| Transmission rate | 9600 bps | |
| Recommended type of cable | Screened or unscreened twisted-pair, 1mm2 | |
| Transmission distance | ≤1000m | |
| Cable diameter | 1mm2 ~ 5mm2 | |
| CAN | Max. number of panels | 20 |
| Transmission rate | Optional: 10K, 20K, 50K and 100K bps | |
| Recommended type of cable | Screened or unscreened twisted-pair, 1mm2 | |
| Transmission distance | ≤1000m | |
| Cable diameter | 1mm2 ~ 5mm2 | |
| Physical dimensions | ||
| Approx. Dimensions of the panel (W×H×D) | 430×560×170mm | |
| Approx. weight (without battery) | 14kg | |
| Operating conditions | ||
| Temperature range: 0°C~ 45°C; Max relative humidity: 95% (40°C ± 2°C, no condensation) | ||