Specifications
Technical specification
Model: BP- MDIIIC | |
General Specifications | |
Outer frame | 2220mm (H) x 820mm (W) x 500mm (D) |
Inner frame | 2000mm (H) x 700mm (W) x 500mm (D) |
Electrical current | AC100V ~ 240V, 50/60Hz |
Power | 10W |
Unit weight | 70kg |
Signal frequency | 7000-8999Hz (adjustable) |
Work environment | -20C to +45C |
Sensitivity adjustable | Level 0-299 |
Alarm | Sound and light |
Max distance | 0.3m at low sensitivity;0.5m at high sensitivity |
Configuration | |
Master control board | Metal-detect-door-mainbd, REV120 |
Digital keypad | A&C door panel board, REV030 |
Digital display location board | A&C door zone board, REV030 |
Light bar | Long bar: metal-detect-door-ledbd,V040 |
Speaker | Loudspeaker, 8 2W, Ω Black, 75mm x 32mm x 27mm |
Software | |
Operation way | Remote control only |
Sensibility | With the highest sensibility, it can detect the metal Article as small as the clip.
With the range of 0-100, it can be adjusted the Sensibility easily, pre-set the weight, volume, size and location in respect of the metal Articles and eliminate the false alarming for the coin, key, jewelry, leather belt button, etc. |
Infrared counting | The intelligent counter can calculate the number of the Passenger flow and the times of alarming. |
Alarm settings | Eight kind of alarm sound |
Detecting areas | Allocation of six mutual over-lapping detecting areas, Simultaneous alarming from multi-areas and accurately ascertaining the location of the metal articles according to the layout of the metal articles. |
Operating Environment | |
Operation temperature/Humidity | 5⁰C ~ 40⁰C / 0%-90% (non-condensing) |
Storage temperature/Humidity | -20⁰C ~ 55⁰C / 0%-98%(non-condensing) |
Operation Power | 220VAC (±10%) 50±3Hz (Optional: 100VAC, 110VAC, 120VAC, 200VAC) |